Crynodeb
This work presents a rapid, calibration-free methodology for constructing high-fidelity digital twins of laboratory X-ray computed-tomography (CT) systems using only radiographs acquired with the instrument itself. By measuring the non-linear relationship between operator-set cathode current and actual anode current, we correct the emitted photon flux and derive a representative flux model through inverse optimisation of image noise. The approach incorporates filtration, scintillator response, detector point-spread function, electronic gain, quantisation, and over-exposure limits, enabling realistic photonic-noise synthesis without specialised dosimetry equipment. Validation on a dual-tube
high-energy (DTHE) micro-focus CT platform demonstrates sub-5% error in signal-to-noise ratio across a broad range of voltages (60–260 kV), currents (50–500 μA), exposures, and gains, and accurate reproduction of material-specific attenuation for aluminium, copper, and steel specimens. Comparisons with
Monte-Carlo (GATE) and analytical (gVirtualXray) simulations confirm that the inverse-derived twins achieve comparable visual and quantitative fidelity while requiring orders of magnitude less computation time (≈0.03 s per projection). Limitations stem from unknown internal filtration and gain-dependent
noise scalingNonetheless, the proposed pipeline provides a practical, reproducible framework for generating digital twins that support rapid prototyping, experimental planning, and advanced data-driven
analyses in X-ray imaging research.
high-energy (DTHE) micro-focus CT platform demonstrates sub-5% error in signal-to-noise ratio across a broad range of voltages (60–260 kV), currents (50–500 μA), exposures, and gains, and accurate reproduction of material-specific attenuation for aluminium, copper, and steel specimens. Comparisons with
Monte-Carlo (GATE) and analytical (gVirtualXray) simulations confirm that the inverse-derived twins achieve comparable visual and quantitative fidelity while requiring orders of magnitude less computation time (≈0.03 s per projection). Limitations stem from unknown internal filtration and gain-dependent
noise scalingNonetheless, the proposed pipeline provides a practical, reproducible framework for generating digital twins that support rapid prototyping, experimental planning, and advanced data-driven
analyses in X-ray imaging research.
| Iaith wreiddiol | Saesneg |
|---|---|
| Rhif yr erthygl | 172109 |
| Cyfnodolyn | Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment |
| Cyfrol | 1094 |
| Dyddiad ar-lein cynnar | 6 Hyd 2026 |
| Dynodwyr Gwrthrych Digidol (DOIs) | |
| Statws | E-gyhoeddi cyn argraffu - 6 Hyd 2026 |
Ôl bys
Gweld gwybodaeth am bynciau ymchwil 'Creating functional digital twins of X-ray CT systems without hassle'. Gyda’i gilydd, maen nhw’n ffurfio ôl bys unigryw.Gwobrau
-
CoSeC Impact Award
Mitchell, I. (Derbynydd) & Vidal, F. (Derbynydd), 26 Mai 2023
Gwobr: Gwobr (gan gynnwys medalau a gwobrau)
-
Runner-up award for best student presentation
Mitchell, I. (Derbynydd) & Vidal, F. (Derbynydd), 12 Hyd 2023
Gwobr: Gwobr (gan gynnwys medalau a gwobrau)
Effeithiau
-
gVirtualXRay: an open source library from Bangor University to simulate X-ray images on GPU in real-time
Vidal, F. (Cyfranogwr)
Effaith: Technegol, Cymdeithasol
Dyfynnu hyn
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver