Evaluation of near infrared spectroscopy and software sensor methods for determination of total alkalinity in anaerobic digesters

  • Aarhus University, Aarhus, Denmark
  • North Wyke Research Station, Devon

Allbwn ymchwil: Cyfraniad at gyfnodolyn › Erthygl › adolygiad gan gymheiriaid

Crynodeb

In this study two approaches to predict the total alkalinity (expressed as mg L(-1)HCO(3)(-)) of an anaerobic digester are examined: firstly, software sensors based on multiple linear regression algorithms using data from pH, redox potential and electrical conductivity and secondly, near infrared reflectance spectroscopy (NIRS). Of the software sensors, the model using data from all three probes but a smaller dataset using total alkalinity values below 6000 mg L(-1)HCO(3)(-) produced the best calibration model (R(2)=0.76 and root mean square error of prediction (RMSEP) of 969 mg L(-1)HCO(3)(-)). When validated with new data, the NIRS method produced the best model (R(2)=0.87 RMSEP=1230 mg L(-1)HCO(3)(-)). The NIRS sensor correlated better with new data (R(2)=0.54). In conclusion, this study has developed new and improved algorithms for monitoring total alkalinity within anaerobic digestion systems which will facilitate real-time optimisation of methane production.

Iaith wreiddiolSaesneg
Tudalennau (o-i)4083-90
Nifer y tudalennau8
CyfnodolynBioresource technology
Cyfrol102
Rhif cyhoeddi5
Dyddiad ar-lein cynnar22 Rhag 2010
Dynodwyr Gwrthrych Digidol (DOIs)
StatwsCyhoeddwyd - 1 Maw 2011

Ôl bys

Gweld gwybodaeth am bynciau ymchwil 'Evaluation of near infrared spectroscopy and software sensor methods for determination of total alkalinity in anaerobic digesters'. Gyda’i gilydd, maen nhw’n ffurfio ôl bys unigryw.

Dyfynnu hyn