Skip to main navigation Skip to search Skip to main content

Interlaboratory study of the operational stability of automated sorption balances.

  • Samuel Zelinka
  • , Samuel Glass
  • , Eleanor Lazarcik
  • , Emil Thybring
  • , Michael Altgen
  • , Lauri Rautkari
  • , Simon Curling
  • , Jinzhen Cao
  • , Yujiao Wang
  • , Tina Kunniger
  • , Gustav Nystrom
  • , Christopher Hubert Dreimol
  • , Ingo Burgert
  • , Mohd Khairhun Anwar Uyup
  • , Tumirah Khadiran
  • , Mark Roper
  • , Darren Broom
  • , Matthew Schwarzkopf
  • , Arief Yudhanto
  • , Mohammad Subah
  • Gilles Lubineau, Maria Fredriksson, Marcin Strojecki, Wieslaw Olek, Jerzy Majka, Nanna Bjerregaard Pedersen, Daniel Burnett, Armando Garcia, Els Verdonck, Frieder Dreisbach, Louis Waguespack, Jennifer Schott, Luis Esteban, Alberto Garcia-Iruela, Thibaut Colinart, Romain Remond, Brahim Mazian, Patrick Perre, Lukas Emmerich, Li Ling
  • US FOrest Service, Forest Products Laboratory, Madison Wisconsin
  • University of Copenhagen
  • Norwegian Insititute of Bioeconomy Research
  • Aalto University
  • Beijing Forestry University
  • EMPA, Dubendorf
  • Forest Research Institute Malaysia, Selangor
  • Hiden Isochema Ltd, Warrington
  • InnoRenew CoE, Slovenia
  • King Abdullah University of Science and Technology (KAUST)
  • Lund University
  • Jerzy Haber Institute of Catalysis and Surface Chemistry, Polish Academy of Sciences
  • University of Life Sciences, Poznan
  • Institute for Conservation, Royal Danish Academy, Copenhagen
  • Surface Measurement Systems Ltd
  • TA instruments
  • TA instruments - Waters LLC
  • Universidad Politechnica de Madrid
  • Universitie Bretagne Sud
  • Universitie de Lorraine
  • Universitie Paris-Saclay
  • University of Göttingen
  • University of Maine

Research output: Contribution to journal › Article › peer-review

67 Downloads (Pure)

Abstract

Automated sorption balances are widely used for characterizing the interaction of water vapor with hygroscopic materials. These instruments provide an efficient way to collect sorption isotherm data and kinetic data. A typical method for defining equilibrium after a step change in relative humidity (RH) is using a particular threshold value for the rate of change in mass with time. Recent studies indicate that commonly used threshold values yield substantial errors and that further measurements are needed at extended hold times as a basis to assess the accuracy of abbreviated equilibration criteria. However, the mass measurement accuracy at extended times depends on the operational stability of the instrument. Published data on the stability of automated sorption balances are rare. An interlaboratory study was undertaken to investigate equilibration criteria for automated sorption balances. This paper focuses on the mass, temperature, and RH stability and includes data from 25 laboratories throughout the world. An initial target for instrument mass stability was met on the first attempt in many cases, but several instruments were found to have unexpectedly large instabilities. The sources of these instabilities were investigated and greatly reduced. This paper highlights the importance of verifying operational mass stability of automated sorption balances, gives a method to perform stability checks, and provides guidance on identifying and correcting common sources of mass instability.
Original languageEnglish
Pages (from-to)1663-1674
Number of pages12
JournalAdsorption
Volume30
Issue number7
Early online date13 Apr 2024
DOIs
Publication statusPublished - 1 Oct 2024

Fingerprint

Dive into the research topics of 'Interlaboratory study of the operational stability of automated sorption balances.'. Together they form a unique fingerprint.

Cite this