gVirtualXRay: Virtual X-Ray Imaging Library on GPU
Allbwn ymchwil: Pennod mewn Llyfr/Adroddiad/Trafodion Cynhadledd › Cyfraniad i Gynhadledd › adolygiad gan gymheiriaid
Fersiynau electronig
Dangosydd eitem ddigidol (DOI)
We present an Open-source library called gVirtualXRay to simulate realistic X-ray images in realtime. It implements the attenuation law (also called Beer-Lambert) on GPU. It takes into account the polychromatism of the beam spectra as well as the finite size of X-ray tubes. The library is written in C++ using modern OpenGL. It is fully portable and works on most common desktop/laptop computers. It has been tested on MS Windows, Linux, and Mac OS X. It supports a wide range of windowing solutions, such as FLTK, GLUT, GLFW3, Qt4, and Qt5. The library also offers realistic visual rendering of anatomical structures, including bones, liver, diaphragm and lungs. The accuracy of the X-ray images produced by gVirtualXRay's implementation has been validated using Geant4, a well established state-of-the-art Monte Carlo simulation toolkit developed by CERN. gVirtualXRay can be used in a wide range of applications where fast and accurate X-ray simulations from polygon meshes are needed, e.g. medical simulators for training purposes, simulation of tomography data acquisition with patient motion to include artefacts in reconstructed CT images, and deformable registration. Our application example package includes real-time respiration and X-ray simulation, CT acquisition and reconstruction, and iso-surfacing of implicit functions using Marching Cubes.
Iaith wreiddiol | Saesneg |
---|---|
Teitl | Computer Graphics & Visual Computing (CGVC) 2017 |
Cyhoeddwr | The Eurographics Association |
Tudalennau | 61-68 |
ISBN (Electronig) | 978-3-03868-050-5 |
Dynodwyr Gwrthrych Digidol (DOIs) | |
Statws | Cyhoeddwyd - 14 Medi 2017 |
Digwyddiad | Computer Graphics & Visual Computing - Manchester Metropolitan University, Manchester, Y Deyrnas Unedig Hyd: 14 Medi 2017 → 15 Medi 2017 http://www.eguk.org.uk/CGVC2017/ |
Cynhadledd
Cynhadledd | Computer Graphics & Visual Computing |
---|---|
Teitl cryno | CGVC |
Gwlad/Tiriogaeth | Y Deyrnas Unedig |
Dinas | Manchester |
Cyfnod | 14/09/17 → 15/09/17 |
Cyfeiriad rhyngrwyd |
Cyhoeddiadau (5)
- Cyhoeddwyd
Use of fast realistic simulations on GPU to extract CAD models from microtomographic data in the presence of strong CT artefacts
Allbwn ymchwil: Cyfraniad at gyfnodolyn › Erthygl › adolygiad gan gymheiriaid
- Cyhoeddwyd
Interactive teaching environment for diagnostic radiography with real-time X-ray simulation and patient positioning
Allbwn ymchwil: Cyfraniad at gyfnodolyn › Erthygl › adolygiad gan gymheiriaid
- Cyhoeddwyd
3D-2D Registration using X-ray Simulation and CMA-ES
Allbwn ymchwil: Cyfraniad at gynhadledd › Papur › adolygiad gan gymheiriaid