Measuring Quality of Life in Carers of People With Dementia: Development and Psychometric Evaluation of Scales measuring the Impact of DEmentia on CARers (SIDECAR)
Allbwn ymchwil: Cyfraniad at gyfnodolyn › Erthygl › adolygiad gan gymheiriaid
StandardStandard
Yn: Gerontologist, Cyfrol 61, Rhif 3, 03.04.2021, t. e1-e11.
Allbwn ymchwil: Cyfraniad at gyfnodolyn › Erthygl › adolygiad gan gymheiriaid
HarvardHarvard
APA
CBE
MLA
VancouverVancouver
Author
RIS
TY - JOUR
T1 - Measuring Quality of Life in Carers of People With Dementia: Development and Psychometric Evaluation of Scales measuring the Impact of DEmentia on CARers (SIDECAR)
AU - Horton, Mike C
AU - Oyebode, Jan
AU - Clare, Linda
AU - Megson, Molly
AU - Shearsmith, Leanne
AU - Brayne, Carol
AU - Kind, Paul
AU - Hoare, Zoe
AU - Al Janabi, Hareth
AU - Hewison, Val
AU - Tennant, Alan
AU - Wright, Penny
PY - 2021/4/3
Y1 - 2021/4/3
N2 - Abstract Background and Objectives A 2008 European consensus on research outcome measures in dementia care concluded that measurement of carer quality of life (QoL) was limited. Three systematic reviews (2012, 2017, and 2018) of dementia carer outcome measures found existing instruments wanting. In 2017, recommendations were published for developing reliable measurement tools of carers’ needs for research and clinical application. The aim of this study was to develop a new instrument to measure the QoL of dementia carers (family/friends). Methods Items were generated directly from carers following an inductive needs-led approach. Carers (n = 566) from 22 English and Welsh locations then completed the items and comparator measures at three time points. Rasch, factor, and psychometric (reliability, validity, responsiveness, and minimally important differences [MIDs]) analyses were undertaken. Results Following factor analysis, the pool of 70 items was refined to three independent scales: primary SIDECAR-D (direct impact of caring upon carer QOL, 18 items), secondary SIDECAR-I (indirect impact, 10 items), and SIDECAR-S (support and information, 11 items). All three scales satisfy Rasch model assumptions. SIDECAR-D, I, S psychometrics: reliability (internal ≥ .70; test–retest ≥ .85); convergent validity (as hypothesized); responsiveness (effect sizes: D: moderate; I and S: small); MIDs (D = 9/100, I = 10/100, S = 11/100). Discussion and Implications SIDECAR scales demonstrate robust measurement properties, meeting COSMIN quality standards for study design and psychometrics. SIDECAR provides a theoretically based needs-led QoL profile specifically for dementia carers. SIDECAR is free for use in public health, social care, and voluntary sector services, and not-for-profit organizations.
AB - Abstract Background and Objectives A 2008 European consensus on research outcome measures in dementia care concluded that measurement of carer quality of life (QoL) was limited. Three systematic reviews (2012, 2017, and 2018) of dementia carer outcome measures found existing instruments wanting. In 2017, recommendations were published for developing reliable measurement tools of carers’ needs for research and clinical application. The aim of this study was to develop a new instrument to measure the QoL of dementia carers (family/friends). Methods Items were generated directly from carers following an inductive needs-led approach. Carers (n = 566) from 22 English and Welsh locations then completed the items and comparator measures at three time points. Rasch, factor, and psychometric (reliability, validity, responsiveness, and minimally important differences [MIDs]) analyses were undertaken. Results Following factor analysis, the pool of 70 items was refined to three independent scales: primary SIDECAR-D (direct impact of caring upon carer QOL, 18 items), secondary SIDECAR-I (indirect impact, 10 items), and SIDECAR-S (support and information, 11 items). All three scales satisfy Rasch model assumptions. SIDECAR-D, I, S psychometrics: reliability (internal ≥ .70; test–retest ≥ .85); convergent validity (as hypothesized); responsiveness (effect sizes: D: moderate; I and S: small); MIDs (D = 9/100, I = 10/100, S = 11/100). Discussion and Implications SIDECAR scales demonstrate robust measurement properties, meeting COSMIN quality standards for study design and psychometrics. SIDECAR provides a theoretically based needs-led QoL profile specifically for dementia carers. SIDECAR is free for use in public health, social care, and voluntary sector services, and not-for-profit organizations.
KW - Carers
KW - Dementia
KW - Quality of Life
KW - Needs-led
KW - Rasch measurement
KW - Psychometrics
U2 - 10.1093/geront/gnz136
DO - 10.1093/geront/gnz136
M3 - Article
VL - 61
SP - e1-e11
JO - Gerontologist
JF - Gerontologist
SN - 0016-9013
IS - 3
ER -