Single Cell Microdosimetric Studies Comparing Ideal and Measured Nanosecond Pulsed Electric Fields
Allbwn ymchwil: Cyfraniad at gynhadledd › Papur
Fersiynau electronig
Dangosydd eitem ddigidol (DOI)
Recently, the promising effects induced by pulsed electric fields with high intensity and short duration have been highlighted. At the nanosecond time scale, electric pulse targets become both the plasmatic membrane and the sub-cellular structures (possibility of intracellular manipulation). In this paper, a circuit cell model with nucleus is presented, validated and used in order to assess the different cellular and sub-cellular (i.e. nucleus) effects, comparing ideal nanosecond pulsed electric fields (nsPEFs) waveforms with the ones measured from a planar, broadband matched microchamber.
Iaith wreiddiol | Saesneg |
---|---|
Dynodwyr Gwrthrych Digidol (DOIs) | |
Statws | Cyhoeddwyd - 2 Meh 2013 |
Digwyddiad | IEEE MTT-S International Microwave Symposium Digest (IMS), Seattle, USA, June 2013 - Hyd: 3 Ion 0001 → … |
Cynhadledd
Cynhadledd | IEEE MTT-S International Microwave Symposium Digest (IMS), Seattle, USA, June 2013 |
---|---|
Cyfnod | 3/01/01 → … |