Electronic versions

  • Sheila Dervis
    University of Ottawa
  • Geoff B Coombs
    University of Ottawa
  • Georgia K Chaseling
    University of Sydney
  • Davide Filingeri
    University of Sydney
  • Jovana Smoljanic
    University of Ottawa
  • Ollie Jay
    University of Ottawa

We sought to determine 1) the influence of adiposity on thermoregulatory responses independently of the confounding biophysical factors of body mass and metabolic heat production (Hprod); and 2) whether differences in adiposity should be accounted for by prescribing an exercise intensity eliciting a fixed Hprod per kilogram of lean body mass (LBM). Nine low (LO-BF) and nine high (HI-BF) body fat males matched in pairs for total body mass (TBM; LO-BF: 88.7 ± 8.4 kg, HI-BF: 90.1 ± 7.9 kg; P = 0.72), but with distinctly different percentage body fat (%BF; LO-BF: 10.8 ± 3.6%; HI-BF: 32.0 ± 5.6%; P < 0.001), cycled for 60 min at 28.1 ± 0.2 °C, 26 ± 8% relative humidity (RH), at a target Hprod of 1) 550 W (FHP trial) and 2) 7.5 W/kg LBM (LBM trial). Changes in rectal temperature (ΔTre) and local sweat rate (LSR) were measured continuously while whole body sweat loss (WBSL) and net heat loss (Hloss) were estimated over 60 min. In the FHP trial, ΔTre (LO-BF: 0.66 ± 0.21 °C, HI-BF: 0.87 ± 0.18 °C; P = 0.02) was greater in HI-BF, whereas mean LSR (LO-BF 0.52 ± 0.19, HI-BF 0.43 ± 0.15 mg·cm(-2)·min(-1); P = 0.19), WBSL (LO-BF 586 ± 82 ml, HI-BF 559 ± 75 ml; P = 0.47) and Hloss (LO-BF 1,867 ± 208 kJ, HI-BF 1,826 ± 224 kJ; P = 0.69) were all similar. In the LBM trial, ΔTre (LO-BF 0.82 ± 0.18 °C, HI-BF 0.54 ± 0.19 °C; P < 0.001), mean LSR (LO-BF 0.59 ± 0.20, HI-BF 0.38 ± 0.12 mg·cm(-2)·min(-1); P = 0.04), WBSL (LO-BF 580 ± 106 ml, HI-BF 381 ± 68 ml; P < 0.001), and Hloss (LO-BF 1,884 ± 277 kJ, HI-BF 1,341 ± 184 kJ; P < 0.001) were all greater at end-exercise in LO-BF. In conclusion, high %BF individuals demonstrate a greater ΔTre independently of differences in mass and Hprod, possibly due to a lower mean specific heat capacity or impaired sudomotor control. However, thermoregulatory responses of groups with different adiposity levels should not be compared using a fixed Hprod in watts per kilogram lean body mass.

Keywords

  • Adipose Tissue/physiology, Adiposity/physiology, Adult, Body Mass Index, Body Temperature/physiology, Body Temperature Regulation/physiology, Exercise/physiology, Hot Temperature, Humans, Male, Sweating/physiology, Thermogenesis/physiology, Young Adult
Original languageEnglish
Pages (from-to)615-23
Number of pages9
JournalJournal of applied physiology (Bethesda, Md. : 1985)
Volume120
Issue number6
DOIs
Publication statusPublished - 15 Mar 2016
Externally publishedYes
View graph of relations