Heat and moisture transfer behaviour in Phyllostachys edulis (Moso bamboo) based panels
Research output: Contribution to journal › Article › peer-review
Standard Standard
In: Construction and Building Materials, No. 166, 30.03.2018, p. 35-49.
Research output: Contribution to journal › Article › peer-review
HarvardHarvard
APA
CBE
MLA
VancouverVancouver
Author
RIS
TY - JOUR
T1 - Heat and moisture transfer behaviour in Phyllostachys edulis (Moso bamboo) based panels
AU - Huang, Puxi
AU - Chew, Y.M.
AU - Chang, Wen-shao
AU - Ansell, Martin
AU - Lawrence, Mike
AU - Latif, Eshrar
AU - Shea, Andy
AU - Ormondroyd, Graham
AU - Du, Hu
PY - 2018/3/30
Y1 - 2018/3/30
N2 - This study focuses on the heat and moisture transfer behaviours in the Phyllostachys edulis (Moso bamboo) panels at various temperature and relative humidity (RH) conditions. Moso bamboo panels with different lamination methods were prepared by assembling bamboo strips from different layers of thebamboo culm wall. Dynamic coupled heat and moisture transfer experiments were conducted.Unsteady state numerical modelling was conducted by COMSOL MultiphysicsTM. A rigorous approach was adopted in this paper. A series of parametric studies of numerical simulation are firstly presented in this paper and then validated by the experiments. Both experimental and simulation results appear to be consistent with the results of measurements of the basic hygrothermal parameters, which demonstrates the robustness of the results. The temperature and RH results indicated that although the panel made from layers of the internal part of bamboo culm wall can provide good insulation performance, its ability to resist high RH variation is inferior to the layer from the external part of bamboo culm wall.The parametric study found that density is the most critical parameters to influence the temperature distributions in the transient state. The thermal conductivity dominates the temperature variation in the steady state. The water vapour diffusion resistance factor is the key parameter which influences theRH simulation results. Numerical simulation with moisture transfer shows better consistency than the simulation without moisture in both equilibrium and transient states. The results of this study demonstrated that the external part of the bamboo culm wall can be utilised to minimise the RH variation of the panel while the internal part is suitable for increasing the thermal insulation performance of the panel.
AB - This study focuses on the heat and moisture transfer behaviours in the Phyllostachys edulis (Moso bamboo) panels at various temperature and relative humidity (RH) conditions. Moso bamboo panels with different lamination methods were prepared by assembling bamboo strips from different layers of thebamboo culm wall. Dynamic coupled heat and moisture transfer experiments were conducted.Unsteady state numerical modelling was conducted by COMSOL MultiphysicsTM. A rigorous approach was adopted in this paper. A series of parametric studies of numerical simulation are firstly presented in this paper and then validated by the experiments. Both experimental and simulation results appear to be consistent with the results of measurements of the basic hygrothermal parameters, which demonstrates the robustness of the results. The temperature and RH results indicated that although the panel made from layers of the internal part of bamboo culm wall can provide good insulation performance, its ability to resist high RH variation is inferior to the layer from the external part of bamboo culm wall.The parametric study found that density is the most critical parameters to influence the temperature distributions in the transient state. The thermal conductivity dominates the temperature variation in the steady state. The water vapour diffusion resistance factor is the key parameter which influences theRH simulation results. Numerical simulation with moisture transfer shows better consistency than the simulation without moisture in both equilibrium and transient states. The results of this study demonstrated that the external part of the bamboo culm wall can be utilised to minimise the RH variation of the panel while the internal part is suitable for increasing the thermal insulation performance of the panel.
M3 - Article
SP - 35
EP - 49
JO - Construction and Building Materials
JF - Construction and Building Materials
SN - 1879-0526
IS - 166
ER -