Simultaneous specimen current and time-dependent cathodoluminescence measurements on gallium nitride
Research output: Contribution to journal › Article › peer-review
Electronic versions
Documents
- Marked Manuscript 2_Campo_JAP - Simultaneous SC and CL_Feb 2016
Accepted author manuscript, 1.7 MB, PDF document
DOI
Other documents
- Supplementary Material_JAP_May 2016
692 KB, PDF document
Time-dependent cathodoluminescence (CL) and specimen current (SC) are monitored to evaluate trapping behavior and evolution of charge storage. Examination of CL and SC suggests that the near band edge emission in GaN is reduced primarily by the activation of traps upon irradiation, and Gallium vacancies are prime candidates. At the steady state, measurement of the stored charge by empiric-analytical methods suggests that all available traps within the interaction volume have been filled, and that additional charge is being stored interstitially, necessarily beyond the interaction volume. Once established, the space charge region is responsible for the steady state CL emission and, prior to build up, it is responsible for the generation of diffusion currents. Since the non-recombination effects resulting from diffusion currents that develop early on are analogous to those leading to device failure upon aging, this study is fundamental toward a holistic insight into optical properties in GaN.
Original language | English |
---|---|
Journal | Journal of Applied Physics |
Volume | 119 |
Issue number | 245108 |
DOIs | |
Publication status | Published - 28 Jun 2016 |
Total downloads
No data available